1.
Int Heart J ; 65(2): 367-370, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38479845

RESUMO

Papillary fibroelastoma (PFE) is a benign tumor that arises mostly from left-sided valves. PFE can cause stroke, and surgical resection may be needed. Lambl's excrescence (LE) is a filiform valvular lesion and is considered a possible cause of stroke. A 79-year-old man with light-headedness and left-sided hemiparesis was diagnosed with stroke. Transesophageal echocardiography (TEE) revealed a round-shaped mobile mass in the left ventricular outflow tract (LVOT), which was considered the cause of the stroke. Surgical resection was performed transaortically, and during surgery, a mass was incidentally detected on the noncoronary cusp (NCC), which was also resected followed by aortic valve replacement. Pathology confirmed that the mass in the LVOT was a PFE and that the filiform mass on the NCC was LE. We herein report a rare case of PFE in the LVOT and coexisting LE on the NCC. A careful examination via TEE helps to identify other possible causes of stroke hidden behind the obvious cause.


Assuntos
Fibroelastoma Papilar Cardíaco , Neoplasias Cardíacas , Doenças das Valvas Cardíacas , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , Doenças das Valvas Cardíacas/complicações , Fibroelastoma Papilar Cardíaco/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Acidente Vascular Cerebral/complicações , Ecocardiografia Transesofagiana , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/diagnóstico por imagem
2.
J Cardiol ; 83(5): 291-297, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37684006

RESUMO

BACKGROUND: Real-time monitoring of generator impedance drop is not considered in CLOSE protocol pulmonary vein (PV) isolation (PVI) in patients with atrial fibrillation (AF). We verified whether additional information of impedance drop could minimize ablation index required for PVI using modified CLOSE protocol (target ablation index ≥ 500 on anterior wall and ≥400 on posterior wall along with inter-lesion distance of 3-6 mm and maximum power of 35 W) without any adverse effect of procedural data and efficacy. METHODS: Sixty consecutive Japanese AF patients [paroxysmal AF: 43 (72 %) patients] underwent first-time PVI with modified CLOSE protocol with real-time monitoring of impedance drop (impedance-guided modified CLOSE protocol). Ablation tags were colored according to impedance drop and ablation was immediately terminated before reaching target ablation index if impedance drop of ≥10â€¯Ω was confirmed. Ablation index needed for PVI, first-pass PVI rate, other procedural data, and atrial tachyarrhythmia recurrence were evaluated. RESULTS: Mean ablation index and impedance drop on anterior and posterior walls were 437.6 ±â€¯43.5â€¯Ω and 10.2 ±â€¯2.6â€¯Ω and 393.3 ±â€¯27.4â€¯Ω and 9.3 ±â€¯2.2 Ω, respectively. First-pass PVI per PV pair was accomplished in 90/120 (75 %). No complications occurred. PV gaps after first-pass ablation were locationally most often found on right posterior wall than on the other parts (p < 0.001). There were no differences in mean contact force, impedance drop, and ablation index between walls with and without PV gaps after first-pass PV ablation. During a mean follow-up of 24 ±â€¯9 months, survival from atrial tachyarrhythmia recurrence was 51/60 (85 %) patients. CONCLUSIONS: Using additional generator impedance drop information may be useful to minimize radiofrequency current application to accomplish PVI with modified CLOSE protocol while maintaining efficacy and safety in Japanese AF population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Impedância Elétrica , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva , Taquicardia
3.
Pacing Clin Electrophysiol ; 47(1): 131-138, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38010718

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are occasionally used in combination with other cardiac implantable electronic devices (CIEDs). However, whether the incidence of inappropriate shock increases in patients with S-ICDs and concomitant CIEDs remains unclear. This study aimed to investigate the association between the concomitant use of CIEDs and the incidence of inappropriate shock in patients with current-generation S-ICDs. METHODS: A total of 127 consecutive patients received an S-ICD. Patients were assigned to two groups depending on concomitant use of CIEDs at the time of S-ICD implantation: patients without other CIEDs (non-combined group, 106 patients) and patients with other CIEDs (combined group, 21 patients). CIEDs included pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy pacemakers, and cardiac resynchronization therapy defibrillators. The primary outcome was inappropriate shock, defined as a shock other than ventricular arrhythmia. Hazard ratios and 95% confidence intervals were calculated using a time-varying Cox proportional hazards model which was adjusted for age because age differed between the groups and could be a confounder. RESULTS: During a median follow-up period of 2.2 years (interquartile range, 1.0-3.4 years), inappropriate shock events occurred in 17 (16%) and five (19%) patients of the non-combined and combined groups, respectively. While the age-adjusted hazard ratio for inappropriate shock was 24% higher in the combined than in the non-combined group (hazard ratio = 1.24, 95% confidence interval, 0.39-3.97), this difference was insignificant (p = .71). CONCLUSION: The incidence of inappropriate shock did not differ between patients with and without concomitant use of CIEDs, suggesting that S-ICDs could potentially be combined with other CIEDs without increasing the number of inappropriate shocks. Further studies are warranted to confirm the safety and feasibility of concomitant use of S-ICDs and CIEDs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos de Coortes , Incidência , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Resultado do Tratamento
4.
Biomed Res ; 44(4): 147-160, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37544736

RESUMO

Tactile perception via whiskers is important in rodent behavior. Whisker trimming during the neonatal period affects mouse behaviors related to both whisker-based tactile cognition and social performance. However, the molecular basis of these phenomena is not completely understood. To solve this issue, we investigated developmental changes in transmitters and metabolites in various brain regions of male mice subjected to bilateral whisker trimming during the neonatal period (10 days after birth [BWT10 mice]). We discovered significantly lower levels of 3-methoxy-4-hydroxyphenyl glycol (MHPG), the major noradrenaline metabolite, in various brain regions of male BWT10 mice at both early/late adolescent stages (at P4W and P8W). However, reduced levels of dopamine (DA) and their metabolites were more significantly identified at P8W in the nuclear origins of monoamine (midbrain and medulla oblongata) and the limbic system (frontal cortex, amygdala, and hippocampus) than at P4W. Furthermore, the onset of social behavior deficits (P6W) was observed later to the impairment of whisker-based tactile cognitive behaviors (P4W). Taken together, these findings suggest that whisker-mediated tactile cognition may contribute toprogressive abnormalities in social behaviors in BWT10 mice accompanied by impaired development of dopaminergic systems.


Assuntos
Comportamento Social , Vibrissas , Camundongos , Animais , Masculino , Encéfalo , Tato , Cognição
5.
J Cardiovasc Electrophysiol ; 34(2): 337-344, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36423234

RESUMO

INTRODUCTION: Spatial characteristics of localized sources of persistent atrial fibrillation (AF) identified by unipolar-based panoramic mapping software (CARTOFINDER) remain unclear. We evaluated spatial characteristics of bi-atrial AF localized sources in relation to complex fractionated atrial electrocardiograms (CFAEs) and atrial low voltage area (LVAs) (≤0.35 mV during AF). METHODS AND RESULTS: Twenty consecutive patients with persistent AF underwent bi-atrial voltage, CFAE, and CARTOFINDER mapping before the beginning of ablation (18 [90%] patients, initial procedure; 2 [10%] patients, repeat procedure). CFAEs were recorded using the interval confidence level (ICL) mode and defined as sites with a confidence level of ≥80% of maximal ICL number. We elucidated the following: (1) differences in the rate of AF localized sources and CFAEs inside or outside the atrial LVAs; (2) distribution of AF localized sources and CFAEs; and (3) distance between the closest points of AF localized sources and CFAEs. A total of 270 AF localized sources and 486 CFAEs were identified in 20 patients. AF localized sources were confirmed more often outside atrial LVAs than CFAEs (71% vs. 46% outside LVA, p < .001). AF localized sources and CFAEs were diffusely distributed without any tendency in bi-atria. Mean distance between closest AF localized sources and CFAEs was 22 ± 8 mm. CONCLUSION: AF localized sources identified by CARTOFINDER are different therapeutic targets as compared to CFAEs and could be confirmed both inside and outside atrial LVAs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Algoritmos , Eletrocardiografia/métodos
6.
J Cardiol Cases ; 26(4): 245-247, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36187320

RESUMO

An 83-year-old male with complete atrioventricular block underwent dual-chamber pacemaker implantation. Venography showed normal anatomy of the left axillary vein. Following sedation with intravenous propofol, local anesthesia, and skin incision, we punctured the left axillary vein on the first limb. However, the guidewire could not be advanced despite blood backflow after the initial puncture. On venography, left axillary vein on the first limb totally disappeared with dilated collaterals. We diagnosed axillary vein spasm and injected 1000 µg of intravenous nitroglycerin. After 15 min, repeated venography showed slight contrast flow in the axillary vein. We alternatively punctured the axillary vein on the second limb. However, the axillary vein was spasmodically occluded again. We considered the possibility that puncture of the right axillary vein could also result in venous spasm. Since the left cephalic vein was identified after waiting time, we partially cut down the left cephalic vein and inserted guidewires into the vein. The ventricular and atrial leads were successfully implanted through sheaths in the right ventricular septum and right atrial appendage, respectively. Learning objective: Pacemaker implantation complicated with puncture-related axillary vein spasm is challenging. Severe venous spasms refractory to waiting time or nitroglycerin sometimes require conversion of access site. However, the bail-out technique from ipsilateral access remains unclear. Cut-down technique of the ipsilateral cephalic vein is one alternative to manage severe axillary vein spasm refractory to nitroglycerin and waiting time.

9.
J Arrhythm ; 38(3): 454-457, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785377

RESUMO

A 69-year-old woman with isolated cardiac sarcoidosis was hospitalized for frequent appropriate implantable converter defibrillator therapies for ventricular tachycardia (VT) despite of favorably controlled condition with oral prednisolone. The patient underwent urgent catheter ablation with CARTO 3D mapping system. Although the voltage map, activation map, and propagation map during VT could not visualize the tachycardia circuit, the coherent map clarified entrance and exit sites of the tachycardia circuit with slow or nonconducting (SNO) zones, which seemed like a figure-of-eight circuit. Considering the risk of VT termination or acceleration to rapid unstable VT, neither entrainment nor pacing studies were performed. The VT was terminated near the exit site of the isthmus where tiny pre-systolic potential was detected. Any diastolic potentials could not be detected. This meant that the critical isthmus might be located at the epicardium or deep incite of the left-ventricular myocardium where the coherent map showed as SNO zones. We should recognize coherent map as artificial that may represent VT circuit as if complete endocardial reentry even if not. The procedural time from mapping to termination of VT was only 22 minutes. The patient has been free from any cardiovascular events after the procedure. Coherent map might be feasible for revealing the critical isthmus of hemodynamically stable VTs without using electrophysiological techniques, including entrainment, pacing study, and voltage map during own beats, and would enable us to achieve successful VT ablation in a short time.

11.
Am J Cardiol ; 178: 52-59, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35817597

RESUMO

The basis for selection of contemporary ablation technologies for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) remains unclear. We compared procedural data and efficacy in a propensity score-matched cohort treated with 4 ablation technologies in a center mainly using cryoballoon (CB). A total of 819 consecutive patients with AF underwent PVI, using radiofrequency current (RFC) (65 patients), CB (693 patients), hot balloon (HB) (74 patients), and laser balloon (LB) (52 patients). Fifty patients (82% paroxysmal AF) were selected from each group according to the propensity score. Procedural data and freedom from atrial tachyarrhythmia recurrence after the index procedure were compared. All pulmonary veins were isolated in all groups. Procedure time was shorter in CB and HB groups (RFC: 148 ± 53 vs CB: 85 ± 37 vs HB: 102 ± 31 vs LB: 140 ± 28 minutes, p <0.001). RFC touch-up was most commonly required for PVI in the HB group among balloon groups (40%) (p <0.001). Total complication rate was 4% to 18% without any statistical differences between groups (p = 0.123). Phrenic nerve injury occurred most often in the CB group (16%) (p <0.001). During a mean follow-up of 21 ± 6 months, there were no significant differences among groups for freedom from atrial tachyarrhythmia recurrence after the index procedure (RFC: 68% vs CB: 78% vs HB: 76% vs LB: 76%, p = 0.440). In conclusion, all the ablation technologies facilitate safe and efficient PVI, with slight differences in the procedural data and complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
12.
Heart Rhythm O2 ; 3(3): 311-318, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734297

RESUMO

Background: The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. Objective: The purpose of this study was to assess lesion characteristics and thermodynamics in LB3 ablation with a RAPID mode in vitro model. Methods: Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.5 W/20 seconds, 10 W/20 seconds, and 12 W/20 seconds. Lesion depth, width, and continuity were compared. Lesion continuity was classified by the visible gap degree categorized from 1 (perfect) to 3 (poor). Thermodynamics and maximum tissue temperatures were assessed under infrared thermographic monitoring. Fifteen and 5 lesions were evaluated per ablation protocol for measurement of lesion size and continuity and for thermographic assessment, respectively. Results: Lesion depth and width were smaller in RAPID mode laser ablation than point-by-point laser ablation (P <.001). However, RAPID mode laser ablation revealed sufficient mean lesion depth of 5 mm or more. Lesion continuity was 1 (perfect) in all samples in RAPID mode laser ablation and point-by-point laser ablation (P = 1). Infrared thermographic observation demonstrated fast and gapless linear lesion formation with thermal stacking in RAPID mode laser ablation. Maximum tissue temperature was lower in RAPID mode laser ablation than point-by-point laser ablation (P <.001). Conclusion: RAPID mode LB3 ablation could provide fast, gapless, and acceptable lesion formation with thermal stacking and moderate tissue temperature rise.

13.
Int J Cardiol Heart Vasc ; 39: 100967, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35146121

RESUMO

BACKGROUND: A surface temperature sensor can be used to visualize the effect of hot balloon (HB) catheters. This study evaluated the efficacy and safety of a second-generation HB system with surface temperature monitoring in patients with atrial fibrillation (AF). METHODS: Twenty patients (age: 69.6 ± 9.7 years, 11 male participants) who underwent first-time pulmonary vein isolation (PVI) using a second-generation HB were included. For each pulmonary vein (PV), the acute isolation rate and effective therapeutic range of surface temperature were investigated. RESULTS: Eighty-three PVs (including three right middle PVs) were isolated in 20 patients using an HB with a surface temperature sensor. Sixty-eight PVs were isolated using the first application. Fifteen PVs (left superior PV [LSPV], n = 7 [35%]; left inferior PV, n = 2 [10%]; right superior PV, n = 3 [15%]; right inferior PV, n = 3 [15%]) showed early intraoperative reconduction and required second applications. One LSPV required radiofrequency touch-up at the carina. The optimal balloon surface temperature and application time were evaluated, and a median value of 58 °C and integral value of 1000 °C·s were identified from the receiver operating characteristic curve to be useful effective indicators. However, for LSPV, the PV potential of carina or ridge likely often remained and needed to be independently considered. There was no periprocedural complication including severe pulmonary vein stenosis. During the observation period (median: 280 days, interquartile range: 261-318 days), 17 patients (85%) achieved and maintained sinus rhythm. CONCLUSIONS: Second-generation HBs with a surface temperature sensor are expected to provide favorable outcomes in AF ablation treatment.

14.
Heart Vessels ; 37(3): 451-459, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34499232

RESUMO

The prognostic predictors of death or heart failure hospitalization and the echocardiographic response after initial cardiac resynchronization therapy (CRT) device replacement (CRT-r) remain unclear. We evaluated the predictors and the echocardiographic time course in patients after CRT-r. Consecutive 60 patients underwent CRT-r because of battery depletion. Patients were divided into two groups depending on the chronic echocardiographic response to CRT (left ventricular end-systolic volume [LVESV] reduction of ≥ 15%) at the time of CRT-r: CRT responders (group A; 35 patients) and CRT nonresponders (group B; 25 patients). The primary endpoint was a composite of death from any cause or heart failure hospitalization. Changes in LVESV and left ventricular ejection fraction (LVEF) after CRT-r were also analyzed. During the mean follow-up of 46 ± 33 months after CRT-r, the primary endpoint occurred more frequently in group B (group A versus group B; 8/35 [23%] patients versus 19/25 [76%] patients, p < 0.001). No significant changes in LVESV and LVEF were observed at the mean of 46 ± 29 months after CRT-r in both groups. A multivariate analysis identified echocardiographic nonresponse to CRT, chronic kidney disease, atrial fibrillation, and New York Heart Association functional class III or IV at the time of CRT-r as independent predictors of the primary endpoint in all patients. Residual echocardiographic nonresponse, comorbidities, and heart failure symptoms at the time of CRT-r predict the subsequent very long-term prognosis after CRT-r. No further echocardiographic response to CRT was found after CRT-r.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Prognóstico , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
15.
PLoS One ; 16(10): e0258830, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34673817

RESUMO

Rett syndrome (RTT) is a neurodevelopmental disorder with X-linked dominant inheritance caused mainly by mutations in the methyl-CpG-binding protein 2 (MECP2) gene. The effects of various Mecp2 mutations have been extensively assessed in mouse models, but none adequately mimic the symptoms and pathological changes of RTT. In this study, we assessed the effects of Mecp2 gene deletion on female rats (Mecp2+/-) and found severe impairments in social behavior [at 8 weeks (w), 12 w, and 23 w of age], motor function [at 16 w and 26 w], and spatial cognition [at 29 w] as well as lower plasma insulin-like growth factor (but not brain-derived neurotrophic factor) and markedly reduced acetylcholine (30%-50%) in multiple brain regions compared to female Mecp2+/+ rats [at 29 w]. Alternatively, changes in brain monoamine levels were relatively small, in contrast to reports on mouse Mecp2 mutants. Female Mecp2-deficient rats express phenotypes resembling RTT and so may provide a robust model for future research on RTT pathobiology and treatment.


Assuntos
Acetilcolina/metabolismo , Encéfalo/metabolismo , Cognição , Locomoção , Memória/fisiologia , Proteína 2 de Ligação a Metil-CpG/fisiologia , Comportamento Social , Animais , Animais Geneticamente Modificados/genética , Animais Geneticamente Modificados/metabolismo , Modelos Animais de Doenças , Feminino , Aprendizagem , Ratos
16.
Clin Case Rep ; 9(8): e04702, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34457301

RESUMO

Heart rate information from a smartwatch can facilitate the diagnosis and treatment of SVT. Benefitting from long-term HR trends, we performed successful RF catheter ablation of coexisting AVNRT and AVRT.

17.
J Arrhythm ; 37(4): 1105-1107, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34386139

RESUMO

The techniques for successful pacemaker implantation via the PLSVC with the SelectSecure system (Medtronic, Minneapolis, Minnesota, USA) are unknown. Regarding the techniques, we presented a case in which we implanted a pacemaker via the PLSVC in patient with absent RSVC using the SelectSecure system.

18.
Heart Rhythm O2 ; 2(4): 347-354, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34430940

RESUMO

BACKGROUND: Optimal overlap ratio remains unclear in point-by-point laser balloon (LB) ablation. OBJECTIVE: This study sought to determine the optimal overlap strategy with target energies on the acute and chronic outcomes in LB pulmonary vein (PV) isolation (PVI). METHODS: Consecutive 38 patients (148 PVs) with atrial fibrillation underwent the first-generation LB PVI with the following protocols based on the overlap ratios for each PV anterior/posterior wall: 50%/50% (13 patients [49 PVs], group A), 50%/25% (15 patients [60 PVs], group B), and 25%/25% (10 patients [39 PVs], group C). High energies (240-255 J: 12 W / 20 seconds, 8.5 W / 30 seconds), moderate energies (200-210 J: 10 W / 20 seconds, 7 W / 30 seconds), and low-to-moderate energies (low, 165-170 J: 5.5 W / 30 seconds, 8.5 W / 20 seconds) were targeted for left PV anterior walls, right PV anterior walls, and bilateral PV posterior walls, respectively. First-pass PVI, the other procedure-related data, and atrial tachyarrhythmia recurrences were analyzed. RESULTS: First-pass PVI rate per PV was higher in group A (94%) than in group B (88%) and group C (62%) (P < .001). All PVs were finally isolated. First-pass time, total LB PVI time, complications, and atrial tachyarrhythmia recurrences during a mean follow-up of 11 ± 5 months did not differ between the groups. A few residual gaps after first-pass LB ablations were found for PV anterior walls even in group A and group B. CONCLUSION: Sufficiently overlapped LB ablation promises a high rate of first-pass PVI without adverse outcomes. High energy could be required for PV anterior walls.

19.
Circ Arrhythm Electrophysiol ; 14(2): e009294, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33417476

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) represents the cornerstone in atrial fibrillation ablation. Cryoballoon and laserballoon catheters have emerged as promising devices but lack randomized comparisons. Therefore, we sought to compare efficacy and safety comparing both balloons in patients with persistent and paroxysmal atrial fibrillation (AF). METHODS: Symptomatic AF patients (n=200) were prospectively randomized (1:1) to receive either cryoballoon or laserballoon PVI (cryoballoon: n=100: 50 paroxysmal atrial fibrillation + 50 persistent AF versus laserballoon: n=100: 50 paroxysmal atrial fibrillation + 50 persistent AF). All antiarrhythmic drugs were stopped after ablation. Follow-up included 3-day Holter-ECG recordings and office visits at 3, 6, and 12 months. Primary efficacy end point was defined as freedom from atrial tachyarrhythmia between 90 and 365 days after a single ablation. Secondary end points included procedural parameters and periprocedural complications. RESULTS: Patient baseline parameters were not different between both groups. In all (n=200) complete PVI was obtained and the entire follow-up accomplished. Balloon only PVI was obtained in 98% (cryoballoon) versus 95% (laserballoon) requiring focal touch-up in 2 and 5 patients, respectively. Procedure but not fluoroscopy time was significantly shorter in the cryoballoon group (50.9±21.0 versus 96.0±20.4 minutes; P<0.0001 and 7.4±4.4 versus 8.4±3.2 minutes, P=0.083). Overall, the primary end point of no atrial tachyarrhythmia recurrence was met in 79% (cryoballoon: 80.0% versus laserballoon: 78.0%, P=ns). No death, atrio-esophageal fistula, tamponade, or vascular laceration requiring surgery occurred. In the cryoballoon group, 8 transient but no persistent phrenic nerve palsy were noted compared with 2 persistent phrenic nerve palsy and one transient ischemic attack in the laserballoon group. CONCLUSIONS: Both balloon technologies represent highly effective and safe tools for PVI resulting in similar favorable rhythm outcome after 12 months. Use of the cryoballoon is associated with significantly shorter procedure but not fluoroscopy time.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Terapia a Laser/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Recidiva , Resultado do Tratamento
20.
J Interv Card Electrophysiol ; 60(1): 135-146, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32144678

RESUMO

PURPOSE: Identification of a conduction gap between the left atrium and pulmonary vein (LA-PV gap) and the circuit of atrial tachycardia after pulmonary vein isolation (PVI) is an important process during the second ablation for atrial fibrillation (AF). The high-density mapping system RHYTHMIA® is useful for identification of an LA-PV gap and the circuit of atrial tachycardia. Therefore, this study was performed to investigate the effect of RHYTHMIA® in terms of the outcome of the second ablation for AF. METHODS: One hundred patients underwent a second ablation for AF in our institute from April 2015 to December 2018. We retrospectively evaluated 49 patients using RHYTHMIA® (group 1) and 51 patients using the conventional method with additional anatomical guide by CARTO® system. RESULTS: In group 1, we performed redo PVI for 41 patients with 49 LA-PV countable gaps and ablation for other atrial arrhythmias in 7 patients. In group 2, we performed redo PVI in 40 patients with 33 LA-PV countable gaps and ablation for other atrial arrhythmias in 9 patients. Three and two unstable arrhythmias in each group were not ablated. The final recurrence of atrial arrhythmia was significantly lower in group 1 than 2 (8/49 (16%) vs. 17/51 (33%), respectively; P = 0.017). Atrial arrhythmias other than AF after the second ablation occurred in only one patient in group 1 but seven patients in group 2. CONCLUSION: Using high-density mapping for the second ablation of AF was found to be superior to the conventional ablation method in terms of the suppression of atrial events in this study. This technique warrants further investigation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento